Operation Dometic Vacuum Status Control Panel
7 Operation
7.1 Vacuum status monitor (g.
3
, page 2)
1. WhenpowerswitchisturnedON,thegreen light indicates that there is sufcient vacuum in the
VacuFlushsystemtoushthetoilet(A).
2. WhenpowerswitchisturnedONandthered light glows, this indicates that there is NOT sufcient
vacuuminthesystemtoushthetoilet(B).Do not flush toilet, or blockage may occur in system.
Notes
Ifgreenandredlightconstantlycycleonandoffbetweenushes,thereisapossible
vacuumleakinthesystem.(AnidleVacuFlushsystemshouldnotcyclemorefrequently
than once every three hours.)
If green light is ON but there is no vacuum in system, a blockage has likely occurred
betweenthetoiletandvacuumtank.Openushballintoiletbowlandusestandardtoilet
plunger to unblock.
After a period of time, if red light seems to remain lit longer than when toilet system was
new, duckbill valves in vacuum pump may require replacement.
Caution!
IfDVS02isconnectedtoa“fulltank”sensorandholdingtankisempty,acontinuousred
light may indicate extensive vacuum loss due to blockage, pump failure or leak. Turn off
vacuum system and repair as soon as possible.
7.2 “Full tank” monitor (onlywhen connected to “full tank” sensor in waste holding tank)
1. WhenpowerswitchisturnedON,theredlightglows,andthevacuumpumpisnotrunning,this
indicates that the holding tank is full and needs to be pumped out. Do not flush toilet, or blockage
may occur in system.
7.3 Circuit breaker control (g.
3
, page 2)
1. TurnthepowerswitchtotheONposition(A,B)fornormaltoiletoperation.Onelightwillalwaysbelit
toindicatethereispowertotheVacuFlushtoiletsystem.Allowsystemvacuumtofullyrechargeand
green light to illuminate before turning power OFF for any reason.
2. Duringthenightorotherextendedperiodswhenthetoiletorvacuumsystemisnotneededto
operate,turnthepowerswitchtotheOFFposition(C).