7
1 Notes on using the manual .................................................7
2 General safety instructions .................................................7
3 Intended use .........................................................7 - 8
4 Components ............................................................8
5 Specications ........................................................8 - 9
6 Installation ..........................................................9 - 10
7 Operation..............................................................11
8 Warranty and Product Liability .........................................11 - 12
1 Notes on using the manual
Note
Supplementary information for operating the device.
fig. 2 A, page 2 : This refers to an element in an illustration. In this example, item A in
gure 2 on page 2.
2
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and
impair the function of the device.
EN
Table of contents
Dometic Tank Monitor System Notes on using the manual
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faultyassemblyorconnection
• Damagetotheunitfrommechanicalinuences,misuseorabuse
• Floatswitchesfouledwithtissuepaper
• Alterationstotheunitwithoutexpresswrittenpermissionfromthemanufacturer
• Useforpurposesotherthanthosedescribedinthismanual
3 Intended use
3.1 OPTION 1: DTM04 tank monitor system
DTM04TankMonitorSystemprovideselectronicmonitoringoftheliquidlevelinsideaholdingtank.
Threeoatswitchesinsidethetankactivateasetoffourlightsonanindicatorpanel.Thelightsindicate
Empty,Low,MidandFulllevels.TheFulllevelindicateswhentheliquidleveliswithin51mm(2in.)of
thetopoftheholdingtank.Theotheroatswitchesareconnectedtoadjustableprobestemswhich
can be positioned according to the tank height and the desired indicator panel readings.
3.2 OPTION 2: DTM04 tank monitor system with “full tank” shut-down relay
Whentheoptional“FullTank”Shut-downRelay(availableseparately)isconnectedtotheDTM04panel,
and the holding tank reaches the Full level, the relay shuts off power to the electric toilet. This prevents
use of the toilet and the possibility of overlling the holding tank. See Components for “Full Tank” Shut-
down Relay item numbers. The relay handles a maximum electrical current of 30 amps.